THE PLATFORM’S DEVELOPMENT RECORD
Technology with a documented foundation.
WAVEPAK integrated Scheimpflug image acquisition, motorized slit rotation and image processing for anterior-segment analysis. The archived design listed a 10 × 10 mm photographic field, a central camera and two lateral USB cameras.
A bright blue LED slit and a two-camera capture system acquired 360 images at one-degree intervals. Slit rotation was microcontroller-controlled at ¼ Hz. Magnification was 1.3×, and the stated working distance/focal distance was 40 mm.
Image processing covered 360 images and four surfaces per image, with 180 measured meridians at one-degree intervals and 162,000 measured points. Software was developed in Brazil for Microsoft Windows.
The archived analysis modules covered topographic and pachymetric maps, anterior and posterior elevation maps and pachymetric-progression curves for investigating ectasia. Corneal aberrometry included Zernike coefficients for all surfaces and PSF and MTF calculations for the whole eye and individual surfaces.
Anterior-chamber analysis included a chamber-depth map and iridocorneal-angle measurement. Crystalline-lens analysis included lens densitometry and cataract investigation. A Holladay-analysis module addressed cataract planning and intraocular-lens calculation for corneas with previous surgery. These are descriptions of the historical modules, not claims of current clinical validation.
The database stored patient and examination records, with backup by copying a single database file to external media, including USB storage. The archived computer specification was a Pentium dual-core processor or better with a 19-inch color LCD or LED monitor.
Electrical specifications were 110/220 V, normal consumption of 65 VA and maximum consumption of 190 VA. Dimensions including the table were 960 mm wide × 1,383 mm high × 396 mm deep; stated weight was 90 kg. A technical-specification PDF accompanies the source.
Instrument, imaging & software gallery
BROCHURES / VIDEOS / SCIENTIFIC REFERENCES
Explore WAVEPAK.
Related scientific publications
Foundational research related to this field. These articles are not clinical validation of a future instrument configuration.
Desenvolvimento e resultados preliminares de um sistema para topografia da córnea utilizando iluminação através de fenda retangular estreita
CARVALHO, LA .
Read the journal / DOI source ↗Original instrument documents & sources
Brochures and manuals link to English EVOptica editions. Historical recordings, source citations and legacy interface screenshots may retain their original language. External archive links may no longer be available.
